2.235.1.1.500.10.8 hwPowerSupply
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.10.8 hwPowerSupply
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwPowerSupply - Relative OID:
2.235.1.1.500.10.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObject 8
Object Definitions
Scalar objects and notifications defined under this node.
hwPowerSupplyFault
- Relative OID:
2.235.1.1.500.10.8.17 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.17 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 17 - Description: Power Supply Fault
hwPowerSupplyFaultDeassert
- Relative OID:
2.235.1.1.500.10.8.18 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.18 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 18 - Description: Power Supply Fault Deassert
hwPowerSupplyPredictiveFailure
- Relative OID:
2.235.1.1.500.10.8.33 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.33 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 33 - Description: Power Supply Predictive Failure
hwPowerSupplyPredictiveFailureDeassert
- Relative OID:
2.235.1.1.500.10.8.34 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.34 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 34 - Description: Power Supply Predictive Failure Deassert
hwPowerSupplyInputLost
- Relative OID:
2.235.1.1.500.10.8.49 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.49 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 49 - Description: Power Supply input lost
hwPowerSupplyInputLostDeassert
- Relative OID:
2.235.1.1.500.10.8.50 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.50 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 50 - Description: Power Supply input lost Deassert
hwPowerSupplyACLost
- Relative OID:
2.235.1.1.500.10.8.65 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.65 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 65 - Description: AC lost or out-of-range
hwPowerSupplyACLostDeassert
- Relative OID:
2.235.1.1.500.10.8.66 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.10.8.66 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwPowerSupply 66 - Description: AC lost or out-of-range Deassert