2.235.1.1.500.11.87 hwNPUEvent
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.500.11.87 hwNPUEvent

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwNPUEvent
  • Relative OID: 2.235.1.1.500.11.87
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 87

Object Definitions

Scalar objects and notifications defined under this node.

hwNPUCoreOverTempMinor

  • Relative OID: 2.235.1.1.500.11.87.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 1
  • Description: NPU core overheating minor alarm. (Generated)

hwNPUCoreOverTempMinorDeassert

  • Relative OID: 2.235.1.1.500.11.87.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 2
  • Description: NPU core overheating minor alarm. (Cleared)

hwNPUCriticalFailure

  • Relative OID: 2.235.1.1.500.11.87.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 3
  • Description: NPU chip health critical alarm. (Generated)

hwNPUCriticalFailureDeassert

  • Relative OID: 2.235.1.1.500.11.87.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.4
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 4
  • Description: NPU chip health critical alarm. (Cleared)

hwNPUMajorFailure

  • Relative OID: 2.235.1.1.500.11.87.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 5
  • Description: NPU chip health major alarm. (Generated)

hwNPUMajorFailureDeassert

  • Relative OID: 2.235.1.1.500.11.87.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 6
  • Description: NPU chip health major alarm. (Cleared)

hwNPUMinorFailure

  • Relative OID: 2.235.1.1.500.11.87.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 7
  • Description: NPU chip health degraded. (Generated)

hwNPUMinorFailureDeassert

  • Relative OID: 2.235.1.1.500.11.87.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 8
  • Description: NPU chip health degraded. (Cleared)

hwNPUOverTempCritical

  • Relative OID: 2.235.1.1.500.11.87.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.9
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 9
  • Description: The OS was shut down due to NPU overheating. (Generated)

hwNPUOverTempCriticalDeassert

  • Relative OID: 2.235.1.1.500.11.87.10
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.10
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 10
  • Description: The OS was shut down due to NPU overheating. (Cleared)

hwNPU12VOverVoltage

  • Relative OID: 2.235.1.1.500.11.87.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 11
  • Description: NPU 12V overvoltage. (Generated)

hwNPU12VOverVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.87.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.12
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 12
  • Description: NPU 12V overvoltage. (Cleared)

hwNPU12V0LowerVoltage

  • Relative OID: 2.235.1.1.500.11.87.13
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.13
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 13
  • Description: NPU 12V undervoltage. (Generated)

hwNPU12V0LowerVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.87.14
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.14
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 14
  • Description: NPU 12V undervoltage. (Cleared)

hwNPUOverVoltage

  • Relative OID: 2.235.1.1.500.11.87.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.15
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 15
  • Description: NPU overvoltage. (Generated)

hwNPUOverVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.87.16
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.16
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 16
  • Description: NPU overvoltage. (Cleared)

hwNPULowerVoltage

  • Relative OID: 2.235.1.1.500.11.87.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.17
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 17
  • Description: NPU undervoltage. (Generated)

hwNPULowerVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.87.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.18
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 18
  • Description: NPU undervoltage. (Cleared)

hwNPUAccessVoltFailure

  • Relative OID: 2.235.1.1.500.11.87.19
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.19
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 19
  • Description: NPU access volt failure. (Generated)

hwNPUAccessVoltFailureDeassert

  • Relative OID: 2.235.1.1.500.11.87.20
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.20
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 20
  • Description: NPU access volt failure. (Cleared)

hwNPUOverTempMinor

  • Relative OID: 2.235.1.1.500.11.87.21
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.21
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 21
  • Description: NPU VRD overtemperature minor alarm. (Generated)

hwNPUOverTempMinorDeassert

  • Relative OID: 2.235.1.1.500.11.87.22
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.22
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 22
  • Description: NPU VRD overtemperature minor alarm. (Cleared)

hwNPUAccessTempFailure

  • Relative OID: 2.235.1.1.500.11.87.23
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.23
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 23
  • Description: NPU VRD access temperature failure. (Generated)

hwNPUAccessTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.87.24
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.24
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 24
  • Description: NPU VRD access temperature failure. (Cleared)

hwNPUEccCountExceed

  • Relative OID: 2.235.1.1.500.11.87.25
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.25
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 25
  • Description: NPU ECC count exceeds threshold (event). (Generated)

hwNPUEccCountExceedDeassert

  • Relative OID: 2.235.1.1.500.11.87.26
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.26
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 26
  • Description: NPU ECC count exceeds threshold (event). (Cleared)

hwNPUEccCountExceedMajor

  • Relative OID: 2.235.1.1.500.11.87.27
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.27
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 27
  • Description: NPU ECC count exceeds threshold (major alarm). (Generated)

hwNPUEccCountExceedMajorDeassert

  • Relative OID: 2.235.1.1.500.11.87.28
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.28
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 28
  • Description: NPU ECC count exceeds threshold (major alarm). (Cleared)

hwNPUCEHardFailure

  • Relative OID: 2.235.1.1.500.11.87.29
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.29
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 29
  • Description: NPU health status degradation detected by PFAE.(Generated)

hwNPUCEHardFailureDeassert

  • Relative OID: 2.235.1.1.500.11.87.30
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.30
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 30
  • Description: NPU health status degradation detected by PFAE.(Cleared)

hwNPUUncorrectableErr

  • Relative OID: 2.235.1.1.500.11.87.31
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.31
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 31
  • Description: NPU triggered an uncorrectable error.(Generated)

hwNPUUncorrectableErrDeassert

  • Relative OID: 2.235.1.1.500.11.87.32
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.87.32
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNPUEvent 32
  • Description: NPU triggered an uncorrectable error.(Cleared)

Back to index