2.235.1.1.500.11.20 hwNCBoardEvent
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.500.11.20 hwNCBoardEvent

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwNCBoardEvent
  • Relative OID: 2.235.1.1.500.11.20
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 20

Object Definitions

Scalar objects and notifications defined under this node.

hwNCBoardOverTemp

  • Relative OID: 2.235.1.1.500.11.20.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 5
  • Description: NCM chip overheating minor alarm. (Generated)

hwNCBoardOverTempDeassert

  • Relative OID: 2.235.1.1.500.11.20.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 6
  • Description: NCM chip overheating minor alarm. (Cleared)

hwNCBoardBandwidthDegrade

  • Relative OID: 2.235.1.1.500.11.20.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 7
  • Description: NCM chip bandwidth decreased by 50% or ECC error. (Generated)

hwNCBoardBandwidthDegradeDeassert

  • Relative OID: 2.235.1.1.500.11.20.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 8
  • Description: NCM chip bandwidth decreased by 50% or ECC error. (Cleared)

hwNCBoardSEV2Fault

  • Relative OID: 2.235.1.1.500.11.20.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.9
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 9
  • Description: SEV2 fault occurred on NCM chip. (Generated)

hwNCBoardSEV2FaultDeassert

  • Relative OID: 2.235.1.1.500.11.20.10
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.10
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 10
  • Description: SEV2 fault occurred on NCM chip. (Cleared)

hwNCBoardAccessTempFailure

  • Relative OID: 2.235.1.1.500.11.20.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 11
  • Description: Failed to read NCM chip temperature. (Generated)

hwNCBoardAccessTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.20.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.12
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 12
  • Description: Failed to read NCM chip temperature. (Cleared)

hwNCBoardCPLDSelfTestFailure

  • Relative OID: 2.235.1.1.500.11.20.13
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.13
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 13
  • Description: NCM CPLD self-test failed. (Generated)

hwNCBoardCPLDSelfTestFailureDeassert

  • Relative OID: 2.235.1.1.500.11.20.14
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.14
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 14
  • Description: NCM CPLD self-test failed. (Cleared)

hwNCBoard12VOverVoltage

  • Relative OID: 2.235.1.1.500.11.20.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.15
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 15
  • Description: NCM 12V overvoltage major alarm. (Generated)

hwNCBoard12VOverVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.20.16
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.16
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 16
  • Description: NCM 12V overvoltage major alarm. (Cleared)

hwNCBoardAccess12VLowerVoltage

  • Relative OID: 2.235.1.1.500.11.20.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.17
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 17
  • Description: NCM 12V undervoltage major alarm. (Generated)

hwNCBoardAccess12VLowerVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.20.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.18
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 18
  • Description: NCM 12V undervoltage major alarm. (Cleared)

hwNCBoardAccess12VFailure

  • Relative OID: 2.235.1.1.500.11.20.19
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.19
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 19
  • Description: Failed to read NCM 12V voltage. (Generated)

hwNCBoardAccess12VFailureDeassert

  • Relative OID: 2.235.1.1.500.11.20.20
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.20
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 20
  • Description: Failed to read NCM 12V voltage. (Cleared)

hwNCBoardConfigCDRFailure

  • Relative OID: 2.235.1.1.500.11.20.65
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.65
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 65
  • Description: Failed to configure CDR of NC board. (Generated)

hwNCBoardConfigCDRFailureDeassert

  • Relative OID: 2.235.1.1.500.11.20.66
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.20.66
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwNCBoardEvent 66
  • Description: Failed to configure CDR of NC board. (Cleared)

Back to index