2.235.1.1.500.11.20 hwNCBoardEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.20 hwNCBoardEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwNCBoardEvent - Relative OID:
2.235.1.1.500.11.20 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 20
Object Definitions
Scalar objects and notifications defined under this node.
hwNCBoardOverTemp
- Relative OID:
2.235.1.1.500.11.20.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 5 - Description: NCM chip overheating minor alarm. (Generated)
hwNCBoardOverTempDeassert
- Relative OID:
2.235.1.1.500.11.20.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 6 - Description: NCM chip overheating minor alarm. (Cleared)
hwNCBoardBandwidthDegrade
- Relative OID:
2.235.1.1.500.11.20.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.7 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 7 - Description: NCM chip bandwidth decreased by 50% or ECC error. (Generated)
hwNCBoardBandwidthDegradeDeassert
- Relative OID:
2.235.1.1.500.11.20.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.8 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 8 - Description: NCM chip bandwidth decreased by 50% or ECC error. (Cleared)
hwNCBoardSEV2Fault
- Relative OID:
2.235.1.1.500.11.20.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.9 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 9 - Description: SEV2 fault occurred on NCM chip. (Generated)
hwNCBoardSEV2FaultDeassert
- Relative OID:
2.235.1.1.500.11.20.10 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.10 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 10 - Description: SEV2 fault occurred on NCM chip. (Cleared)
hwNCBoardAccessTempFailure
- Relative OID:
2.235.1.1.500.11.20.11 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.11 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 11 - Description: Failed to read NCM chip temperature. (Generated)
hwNCBoardAccessTempFailureDeassert
- Relative OID:
2.235.1.1.500.11.20.12 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.12 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 12 - Description: Failed to read NCM chip temperature. (Cleared)
hwNCBoardCPLDSelfTestFailure
- Relative OID:
2.235.1.1.500.11.20.13 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.13 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 13 - Description: NCM CPLD self-test failed. (Generated)
hwNCBoardCPLDSelfTestFailureDeassert
- Relative OID:
2.235.1.1.500.11.20.14 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.14 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 14 - Description: NCM CPLD self-test failed. (Cleared)
hwNCBoard12VOverVoltage
- Relative OID:
2.235.1.1.500.11.20.15 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.15 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 15 - Description: NCM 12V overvoltage major alarm. (Generated)
hwNCBoard12VOverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.20.16 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.16 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 16 - Description: NCM 12V overvoltage major alarm. (Cleared)
hwNCBoardAccess12VLowerVoltage
- Relative OID:
2.235.1.1.500.11.20.17 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.17 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 17 - Description: NCM 12V undervoltage major alarm. (Generated)
hwNCBoardAccess12VLowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.20.18 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.18 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 18 - Description: NCM 12V undervoltage major alarm. (Cleared)
hwNCBoardAccess12VFailure
- Relative OID:
2.235.1.1.500.11.20.19 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.19 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 19 - Description: Failed to read NCM 12V voltage. (Generated)
hwNCBoardAccess12VFailureDeassert
- Relative OID:
2.235.1.1.500.11.20.20 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.20 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 20 - Description: Failed to read NCM 12V voltage. (Cleared)
hwNCBoardConfigCDRFailure
- Relative OID:
2.235.1.1.500.11.20.65 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.65 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 65 - Description: Failed to configure CDR of NC board. (Generated)
hwNCBoardConfigCDRFailureDeassert
- Relative OID:
2.235.1.1.500.11.20.66 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.20.66 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwNCBoardEvent 66 - Description: Failed to configure CDR of NC board. (Cleared)