2.235.1.1.500.11.12 hwMezzCardEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.12 hwMezzCardEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwMezzCardEvent - Relative OID:
2.235.1.1.500.11.12 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 12
Object Definitions
Scalar objects and notifications defined under this node.
hwMezzCardOverTempMinor
- Relative OID:
2.235.1.1.500.11.12.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.1 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 1 - Description: Mezzanine card overheating minor alarm. (Generated)
hwMezzCardOverTempMinorDeassert
- Relative OID:
2.235.1.1.500.11.12.2 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.2 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 2 - Description: Mezzanine card overheating minor alarm. (Cleared)
hwMezzCardOverTempMajor
- Relative OID:
2.235.1.1.500.11.12.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.3 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 3 - Description: Mezzanine card overheating major alarm. (Generated)
hwMezzCardOverTempMajorDeassert
- Relative OID:
2.235.1.1.500.11.12.4 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.4 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 4 - Description: Mezzanine card overheating major alarm. (Cleared)
hwMezzCardUncorrectableErr
- Relative OID:
2.235.1.1.500.11.12.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 5 - Description: Mezzanine card MCE/AER error. (Generated)
hwMezzCardUncorrectableErrDeassert
- Relative OID:
2.235.1.1.500.11.12.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 6 - Description: Mezzanine card MCE/AER error. (Cleared)
hwMezzCardAccessTempFailure
- Relative OID:
2.235.1.1.500.11.12.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.7 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 7 - Description: Failed to read mezzanine card temperature. (Generated)
hwMezzCardAccessTempFailureDeassert
- Relative OID:
2.235.1.1.500.11.12.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.8 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 8 - Description: Failed to read mezzanine card temperature. (Cleared)
hwMezzCardAccessFRULableFailure
- Relative OID:
2.235.1.1.500.11.12.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.9 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 9 - Description: Failed to read mezzanine card electronic label. (Generated)
hwMezzCardAccessFRULableFailureDeassert
- Relative OID:
2.235.1.1.500.11.12.10 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.10 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 10 - Description: Failed to read mezzanine card electronic label. (Cleared)
hwMezzCardOverVoltage
- Relative OID:
2.235.1.1.500.11.12.11 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.11 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 11 - Description: Mezzanine card overvoltage major alarm. (Generated)
hwMezzCardOverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.12.12 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.12 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 12 - Description: Mezzanine card overvoltage major alarm. (Cleared)
hwMezzCardLowerVoltage
- Relative OID:
2.235.1.1.500.11.12.13 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.13 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 13 - Description: Mezzanine card undervoltage major alarm. (Generated)
hwMezzCardLowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.12.14 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.14 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 14 - Description: Mezzanine card undervoltage major alarm. (Cleared)
hwMezzCardSVIDChipFailure
- Relative OID:
2.235.1.1.500.11.12.31 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.31 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 31 - Description: Mezzanine card failed to obtain WFR chip SVID. (Generated)
hwMezzCardSVIDChipFailureDeassert
- Relative OID:
2.235.1.1.500.11.12.32 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.32 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 32 - Description: Mezzanine card failed to obtain WFR chip SVID. (Cleared)
hwMezzCardVoltageFailure
- Relative OID:
2.235.1.1.500.11.12.33 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.33 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 33 - Description: Failed to read mezzanine card voltage. (Generated)
hwMezzCardVoltageFailureDeassert
- Relative OID:
2.235.1.1.500.11.12.34 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.34 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 34 - Description: Failed to read mezzanine card voltage. (Cleared)
hwMezzCardCEHardFailure
- Relative OID:
2.235.1.1.500.11.12.35 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.35 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 35 - Description: Mezzanine card health status degradation detected by PFAE. (Generated)
hwMezzCardCEHardFailureDeassert
- Relative OID:
2.235.1.1.500.11.12.36 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.36 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 36 - Description: Mezzanine card health status degradation detected by PFAE. (Cleared)
hwMezzCardNotInstalled
- Relative OID:
2.235.1.1.500.11.12.37 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.12.37 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMezzCardEvent 37 - Description: The mezzanine card is not installed.