2.235.1.1.500.11.15 hwMemoryBoardEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.15 hwMemoryBoardEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwMemoryBoardEvent - Relative OID:
2.235.1.1.500.11.15 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.15 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 15
Object Definitions
Scalar objects and notifications defined under this node.
hwMemoryBoardLowerTemp
- Relative OID:
2.235.1.1.500.11.15.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.15.1 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMemoryBoardEvent 1 - Description: Memory board undertemperature. (Generated)
hwMemoryBoardLowerTempDeassert
- Relative OID:
2.235.1.1.500.11.15.2 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.15.2 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMemoryBoardEvent 2 - Description: Memory board undertemperature. (Cleared)
hwMemoryBoardAccessTempFailure
- Relative OID:
2.235.1.1.500.11.15.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.15.3 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMemoryBoardEvent 3 - Description: Failed to read memory board temperature. (Generated)
hwMemoryBoardAccessTempFailureDeassert
- Relative OID:
2.235.1.1.500.11.15.4 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.15.4 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMemoryBoardEvent 4 - Description: Failed to read memory board temperature. (Cleared)
hwMemoryBoardSMI2TainingError
- Relative OID:
2.235.1.1.500.11.15.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.15.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMemoryBoardEvent 5 - Description: Initialization error on SMI2 link of memory board. (Generated)
hwMemoryBoardSMI2TainingErrorDeassert
- Relative OID:
2.235.1.1.500.11.15.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.15.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwMemoryBoardEvent 6 - Description: Initialization error on SMI2 link of memory board. (Cleared)