2.235.1.1.500.11.65 hwGPUCarrierBoardEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.65 hwGPUCarrierBoardEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwGPUCarrierBoardEvent - Relative OID:
2.235.1.1.500.11.65 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 65
Object Definitions
Scalar objects and notifications defined under this node.
hwGPUCarrierBoardlowerVoltage
- Relative OID:
2.235.1.1.500.11.65.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.1 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 1 - Description: xPU carrier board voltage below lower major threshold. (Generated)
hwGPUCarrierBoardlowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.65.2 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.2 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 2 - Description: xPU carrier board voltage below lower major threshold. (Cleared)
hwGPUCarrierBoardOverVoltage
- Relative OID:
2.235.1.1.500.11.65.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.3 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 3 - Description: xPU carrier board overvoltage major alarm. (Generated)
hwGPUCarrierBoardOverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.65.4 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.4 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 4 - Description: xPU carrier board overvoltage major alarm. (Cleared)
hwGPUCarrierBoardAccessVoltageFailure
- Relative OID:
2.235.1.1.500.11.65.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 5 - Description: Failed to obtain the voltage of xPU carrier board.(Generated)
hwGPUCarrierBoardAccessVoltageFailureDeassert
- Relative OID:
2.235.1.1.500.11.65.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 6 - Description: Failed to obtain the voltage of xPU carrier board.(Cleared)
hwGPUCarrierBoardOverTempMinor
- Relative OID:
2.235.1.1.500.11.65.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.7 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 7 - Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Generated)
hwGPUCarrierBoardOverTempMinorDeassert
- Relative OID:
2.235.1.1.500.11.65.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.8 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 8 - Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Cleared)
hwGPUCarrierBoardAccessTempFailure
- Relative OID:
2.235.1.1.500.11.65.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.9 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 9 - Description: Failed to obtain the temperature at detection point on the xPU carrier board.(Generated)
hwGPUCarrierBoardAccessTempFailureDeassert
- Relative OID:
2.235.1.1.500.11.65.10 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.10 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 10 - Description: Failed to obtain the temperature at detection point on the xPU carrier board.(Cleared)
hwGPUCarrierBoardClockSignalLost
- Relative OID:
2.235.1.1.500.11.65.11 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.11 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 11 - Description: xPU carrier board clock signals lost.(Generated)
hwGPUCarrierBoardClockSignalLostDeassert
- Relative OID:
2.235.1.1.500.11.65.12 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.12 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 12 - Description: xPU carrier board clock signals lost.(Cleared)
hwGPUCarrierBoardCPLDSelfTestFailure
- Relative OID:
2.235.1.1.500.11.65.13 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.13 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 13 - Description: xPU carrier board CPLD self-check error.(Generated)
hwGPUCarrierBoardCPLDSelfTestFailureDeassert
- Relative OID:
2.235.1.1.500.11.65.14 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.14 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 14 - Description: xPU carrier board CPLD self-check error.(Cleared)
hwGPUCarrierBoardAccessPowerFailure
- Relative OID:
2.235.1.1.500.11.65.15 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.15 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 15 - Description: Failed to obtain the power of xPU carrier board.(Generated)
hwGPUCarrierBoardAccessPowerFailureDeassert
- Relative OID:
2.235.1.1.500.11.65.16 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.16 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 16 - Description: Failed to obtain the power of xPU carrier board.(Cleared)
hwGPUCarrierBoardPowerOnFailure
- Relative OID:
2.235.1.1.500.11.65.17 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.17 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 17 - Description: Failed to power on xPU carrier board.(Generated)
hwGPUCarrierBoardPowerOnFailureDeassert
- Relative OID:
2.235.1.1.500.11.65.18 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.18 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 18 - Description: Failed to power on xPU carrier board.(Cleared)
hwGPUCarrierBoardInstalled
- Relative OID:
2.235.1.1.500.11.65.19 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.19 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 19 - Description: xPU carrier board installed.
hwGPUCarrierBoardRemoved
- Relative OID:
2.235.1.1.500.11.65.21 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.21 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 21 - Description: xPU carrier board removed.
hwGPUCarrierBoardMOSOverTemp
- Relative OID:
2.235.1.1.500.11.65.23 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.23 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 23 - Description: The soft-start circuit MOS FET temperature at detection point of xPU carrier board is too high. (Generated)
hwGPUCarrierBoardMOSOverTempDeassert
- Relative OID:
2.235.1.1.500.11.65.24 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.24 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 24 - Description: The soft-start circuit MOS FET temperature at detection point of xPU carrier board is too high. (Cleared)
hwGPUCarrierBoardSoftStartPGAbnormal
- Relative OID:
2.235.1.1.500.11.65.25 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.25 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 25 - Description: The soft-start circuit power supply at detection point of xPU carrier board is abnormal. (Generated)
hwGPUCarrierBoardSoftStartPGAbnormalDeassert
- Relative OID:
2.235.1.1.500.11.65.26 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.26 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 26 - Description: The soft-start circuit power supply at detection point of xPU carrier board is abnormal. (Cleared)
hwGPUCarrierBoardGPUThermalOver
- Relative OID:
2.235.1.1.500.11.65.29 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.29 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 29 - Description: MOS temperature on xPU carrier board exceeds the protection point. (Generated)
hwGPUCarrierBoardGPUThermalOverDeassert
- Relative OID:
2.235.1.1.500.11.65.30 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.30 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 30 - Description: MOS temperature on xPU carrier board exceeds the protection point. (Cleared)
hwGPUCarrierBoardOverTempMajor
- Relative OID:
2.235.1.1.500.11.65.31 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.31 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 31 - Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Generated)
hwGPUCarrierBoardOverTempMajorDeassert
- Relative OID:
2.235.1.1.500.11.65.32 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.32 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 32 - Description: xPU carrier board temperature at detection point exceeds the overtemperature threshold.(Cleared)
hwGPUCarrierBoardCEHardFailure
- Relative OID:
2.235.1.1.500.11.65.37 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.37 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 37 - Description: xPU carrier board health status degradation detected by PFAE.(Generated)
hwGPUCarrierBoardCEHardFailureDeassert
- Relative OID:
2.235.1.1.500.11.65.38 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.38 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 38 - Description: xPU carrier board health status degradation detected by PFAE.(Cleared)
hwGPUCarrierBoardReplaced
- Relative OID:
2.235.1.1.500.11.65.39 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.39 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 39 - Description: GPU board replaced.(Generated)
hwGPUCarrierBoardUCEHardFailure
- Relative OID:
2.235.1.1.500.11.65.41 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.41 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 41 - Description: xPU carrier board has triggered an uncorrectable error.(Generated)
hwGPUCarrierBoardUCEHardFailureDeassert
- Relative OID:
2.235.1.1.500.11.65.42 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.65.42 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwGPUCarrierBoardEvent 42 - Description: xPU carrier board has triggered an uncorrectable error.(Cleared)