2.235.1.1.500.11.25 hwFanBoardEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.25 hwFanBoardEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwFanBoardEvent - Relative OID:
2.235.1.1.500.11.25 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 25
Object Definitions
Scalar objects and notifications defined under this node.
hwFanBoardOverTemp
- Relative OID:
2.235.1.1.500.11.25.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.1 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 1 - Description: Fan backplane power supply over temperature.(Generated)
hwFanBoardOverTempDeassert
- Relative OID:
2.235.1.1.500.11.25.2 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.2 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 2 - Description: Fan backplane power supply over temperature.(Cleared)
hwFanBoardPowerFailure
- Relative OID:
2.235.1.1.500.11.25.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.3 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 3 - Description: Fan backplane power failure.(Generated)
hwFanBoardPowerFailureDeassert
- Relative OID:
2.235.1.1.500.11.25.4 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.4 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 4 - Description: Fan backplane power failure.(Cleared)
hwFanBoardReplaced
- Relative OID:
2.235.1.1.500.11.25.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 5 - Description: FanBoard replaced.(Generated)
hwFanBoardSoftStartOverTemp
- Relative OID:
2.235.1.1.500.11.25.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.7 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 7 - Description: High temperature of soft-start circuit of the fan backplane.(Generated)
hwFanBoardSoftStartOverTempDeassert
- Relative OID:
2.235.1.1.500.11.25.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.8 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 8 - Description: High temperature of soft-start circuit of the fan backplane.(Cleared)
hwFanBoardCPLDSelfTestFailure
- Relative OID:
2.235.1.1.500.11.25.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.9 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 9 - Description: Fan backplane CPLD self-test failed.(Generated)
hwFanBoardCPLDSelfTestFailureDeassert
- Relative OID:
2.235.1.1.500.11.25.10 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.25.10 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwFanBoardEvent 10 - Description: Fan backplane CPLD self-test failed.(Cleared)