2.235.1.1.500.11.31 hwFabricPlaneEvent
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.500.11.31 hwFabricPlaneEvent

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwFabricPlaneEvent
  • Relative OID: 2.235.1.1.500.11.31
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 31

Object Definitions

Scalar objects and notifications defined under this node.

hwFabricPlaneLSWVDDLowerVoltage

  • Relative OID: 2.235.1.1.500.11.31.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 1
  • Description: Fabric plane LSW chip VDD undervoltage major alarm. (Generated)

hwFabricPlaneLSWVDDLowerVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.31.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 2
  • Description: Fabric plane LSW chip VDD undervoltage major alarm. (Cleared)

hwFabricPlaneLSWVDDOverVoltage

  • Relative OID: 2.235.1.1.500.11.31.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 3
  • Description: Fabric plane LSW chip VDD overvoltage major alarm. (Generated)

hwFabricPlaneLSWVDDOverVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.31.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.4
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 4
  • Description: Fabric plane LSW chip VDD overvoltage major alarm. (Cleared)

hwFabricPlaneLSWVcoreLowerVoltage

  • Relative OID: 2.235.1.1.500.11.31.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 5
  • Description: Fabric plane LSW chip Vcore undervoltage major alarm. (Generated)

hwFabricPlaneLSWVcoreLowerVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.31.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 6
  • Description: Fabric plane LSW chip Vcore undervoltage major alarm. (Cleared)

hwFabricPlaneLSWVcoreOverVoltage

  • Relative OID: 2.235.1.1.500.11.31.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 7
  • Description: Fabric plane LSW chip Vcore overvoltage major alarm. (Generated)

hwFabricPlaneLSWVcoreOverVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.31.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 8
  • Description: Fabric plane LSW chip Vcore overvoltage major alarm. (Cleared)

hwFabricPlaneLSWOverTempMinor

  • Relative OID: 2.235.1.1.500.11.31.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.9
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 9
  • Description: Fabric plane LSW chip overheating minor alarm. (Generated)

hwFabricPlaneLSWOverTempMinorDeassert

  • Relative OID: 2.235.1.1.500.11.31.10
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.10
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 10
  • Description: Fabric plane LSW chip overheating minor alarm. (Cleared)

hwFabricPlaneLSWOverTempMajor

  • Relative OID: 2.235.1.1.500.11.31.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 11
  • Description: Fabric plane LSW chip overheating major alarm. (Generated)

hwFabricPlaneLSWOverTempMajorDeassert

  • Relative OID: 2.235.1.1.500.11.31.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.12
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 12
  • Description: Fabric plane LSW chip overheating major alarm. (Cleared)

hwFabricPlaneCPUOverTempMinor

  • Relative OID: 2.235.1.1.500.11.31.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.15
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 15
  • Description: Fabric plane CPU overheating minor alarm. (Generated)

hwFabricPlaneCPUOverTempMinorDeassert

  • Relative OID: 2.235.1.1.500.11.31.16
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.16
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 16
  • Description: Fabric plane CPU overheating minor alarm. (Cleared)

hwFabricPlaneCPUOverTempMajor

  • Relative OID: 2.235.1.1.500.11.31.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.17
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 17
  • Description: Fabric plane CPU overheating major alarm. (Generated)

hwFabricPlaneCPUOverTempMajorDeassert

  • Relative OID: 2.235.1.1.500.11.31.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.18
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 18
  • Description: Fabric plane CPU overheating major alarm. (Cleared)

hwFabricPlaneLSWFault

  • Relative OID: 2.235.1.1.500.11.31.21
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.21
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 21
  • Description: Fabric plane LSW chip fault. (Generated)

hwFabricPlaneLSWFaultDeassert

  • Relative OID: 2.235.1.1.500.11.31.22
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.22
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 22
  • Description: Fabric plane LSW chip fault. (Cleared)

hwFabricPlaneNotInstalled

  • Relative OID: 2.235.1.1.500.11.31.23
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.23
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 23
  • Description: Fabric module not installed.

hwFabricPlanePowerOff

  • Relative OID: 2.235.1.1.500.11.31.25
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.25
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 25
  • Description: Fabric module installed but powered off.

hwFabricPlaneReqPowerOn

  • Relative OID: 2.235.1.1.500.11.31.27
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.27
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 27
  • Description: Fabric module requesting power-on.

hwFabricPlaneBeingPoweredOn

  • Relative OID: 2.235.1.1.500.11.31.29
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.29
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 29
  • Description: Fabric module in power-on process.

hwFabricPlanePoweredOn

  • Relative OID: 2.235.1.1.500.11.31.31
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.31
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 31
  • Description: Fabric module powered on.

hwFabricPlaneReqPoweredOff

  • Relative OID: 2.235.1.1.500.11.31.33
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.33
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 33
  • Description: Fabric module requesting power-off.

hwFabricPlaneInProgressPoweredOff

  • Relative OID: 2.235.1.1.500.11.31.35
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.35
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 35
  • Description: Fabric module in power-off process.

hwFabricPlaneLSWAccessVDDFailure

  • Relative OID: 2.235.1.1.500.11.31.39
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.39
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 39
  • Description: Failed to read Fabric plane LSW chip VDD voltage. (Generated)

hwFabricPlaneLSWAccessVDDFailureDeassert

  • Relative OID: 2.235.1.1.500.11.31.40
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.40
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 40
  • Description: Failed to read Fabric plane LSW chip VDD voltage. (Cleared)

hwFabricPlaneLSWAccessVcoreFailure

  • Relative OID: 2.235.1.1.500.11.31.41
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.41
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 41
  • Description: Failed to read Fabric plane LSW chip Vcore voltage. (Generated)

hwFabricPlaneLSWAccessVcoreFailureDeassert

  • Relative OID: 2.235.1.1.500.11.31.42
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.42
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 42
  • Description: Failed to read Fabric plane LSW chip Vcore voltage. (Cleared)

hwFabricPlaneLSWAccessTempFailure

  • Relative OID: 2.235.1.1.500.11.31.43
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.43
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 43
  • Description: Failed to read Fabric plane LSW temperature. (Generated)

hwFabricPlaneLSWAccessTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.31.44
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.44
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 44
  • Description: Failed to read Fabric plane LSW temperature. (Cleared)

hwFabricPlaneLSWAccessCPUTempFailure

  • Relative OID: 2.235.1.1.500.11.31.45
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.45
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 45
  • Description: Failed to read Fabric plane CPU temperature. (Generated)

hwFabricPlaneLSWAccessCPUTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.31.46
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.46
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 46
  • Description: Failed to read Fabric plane CPU temperature. (Cleared)

hwFabricPlaneSWLowerVoltMajor

  • Relative OID: 2.235.1.1.500.11.31.47
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.47
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 47
  • Description: Fabric plane switch voltage below lower major threshold. (Generated)

hwFabricPlaneSWLowerVoltMajorDeassert

  • Relative OID: 2.235.1.1.500.11.31.48
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.48
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 48
  • Description: Fabric plane switch voltage below lower major threshold. (Cleared)

hwFabricPlaneSWOverVoltMajor

  • Relative OID: 2.235.1.1.500.11.31.49
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.49
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 49
  • Description: Fabric plane switch overvoltage major alarm. (Generated)

hwFabricPlaneSWOverVoltMajorDeassert

  • Relative OID: 2.235.1.1.500.11.31.50
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.50
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 50
  • Description: Fabric plane switch overvoltage major alarm. (Cleared)

hwFabricPlaneSWAccessVoltFailure

  • Relative OID: 2.235.1.1.500.11.31.51
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.51
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 51
  • Description: Failed to read Fabric plane switch voltage. (Generated)

hwFabricPlaneSWAccessVoltFailureDeassert

  • Relative OID: 2.235.1.1.500.11.31.52
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.52
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 52
  • Description: Failed to read Fabric plane switch voltage. (Cleared)

hwFabricPlaneSWOverTempMinor

  • Relative OID: 2.235.1.1.500.11.31.53
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.53
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 53
  • Description: Fabric plane switch overheating minor alarm. (Generated)

hwFabricPlaneSWOverTempMinorDeassert

  • Relative OID: 2.235.1.1.500.11.31.54
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.54
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 54
  • Description: Fabric plane switch overheating minor alarm. (Cleared)

hwFabricPlaneSWOverTempMajor

  • Relative OID: 2.235.1.1.500.11.31.55
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.55
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 55
  • Description: Fabric plane switch overheating major alarm. (Generated)

hwFabricPlaneSWOverTempMajorDeassert

  • Relative OID: 2.235.1.1.500.11.31.56
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.56
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 56
  • Description: Fabric plane switch overheating major alarm. (Cleared)

hwFabricPlaneSWFault

  • Relative OID: 2.235.1.1.500.11.31.57
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.57
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 57
  • Description: Fabric plane switch fault. (Generated)

hwFabricPlaneSWFaultDeassert

  • Relative OID: 2.235.1.1.500.11.31.58
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.58
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 58
  • Description: Fabric plane switch fault. (Cleared)

hwFabricPlaneSWEEPROMFault

  • Relative OID: 2.235.1.1.500.11.31.59
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.59
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 59
  • Description: Fabric plane switch EEPROM fault. (Generated)

hwFabricPlaneSWEEPROMFaultDeassert

  • Relative OID: 2.235.1.1.500.11.31.60
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.60
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 60
  • Description: Fabric plane switch EEPROM fault. (Cleared)

hwFabricPlaneSWClock

  • Relative OID: 2.235.1.1.500.11.31.61
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.61
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 61
  • Description: Fabric plane switch clock abnormal. (Generated)

hwFabricPlaneSWClockDeassert

  • Relative OID: 2.235.1.1.500.11.31.62
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.62
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 62
  • Description: Fabric plane switch clock abnormal. (Cleared)

hwFabricPlaneRestart

  • Relative OID: 2.235.1.1.500.11.31.63
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.63
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 63
  • Description: Fabric plane Restart.

hwFabricPlaneSWAccessSVIDFailure

  • Relative OID: 2.235.1.1.500.11.31.65
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.65
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 65
  • Description: Failed to obtain the switch chip SVID value for the Fabric plane. (Generated)

hwFabricPlaneSWAccessSVIDFailureDeassert

  • Relative OID: 2.235.1.1.500.11.31.66
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.31.66
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwFabricPlaneEvent 66
  • Description: Failed to obtain the switch chip SVID value for the Fabric plane. (Cleared)

Back to index