2.235.1.1.500.11.51 hwExpanderEvent
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.500.11.51 hwExpanderEvent

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwExpanderEvent
  • Relative OID: 2.235.1.1.500.11.51
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 51

Object Definitions

Scalar objects and notifications defined under this node.

hwExpanderFault

  • Relative OID: 2.235.1.1.500.11.51.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 1
  • Description: Hard disk backplane expander fault. (Generated)

hwExpanderFaultDeassert

  • Relative OID: 2.235.1.1.500.11.51.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 2
  • Description: Hard disk backplane expander fault. (Cleared)

hwExpanderCommFault

  • Relative OID: 2.235.1.1.500.11.51.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 3
  • Description: Communication between expander and RAID card failed. (Generated)

hwExpanderCommFaultDeassert

  • Relative OID: 2.235.1.1.500.11.51.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.4
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 4
  • Description: Communication between expander and RAID card failed. (Cleared)

hwExpanderToRAIDLinkPHYFault

  • Relative OID: 2.235.1.1.500.11.51.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 5
  • Description: The PHY bit errors of the link between expander and RAID card increased too fast. (Generated)

hwExpanderToRAIDLinkPHYFaultDeassert

  • Relative OID: 2.235.1.1.500.11.51.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.6
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 6
  • Description: The PHY bit errors of the link between expander and RAID card increased too fast. (Cleared)

hwExpanderToExpanderLinkPHYFault

  • Relative OID: 2.235.1.1.500.11.51.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 7
  • Description: The PHY bit errors of the link between expander and expander increased too fast. (Generated)

hwExpanderToExpanderLinkPHYFaultDeassert

  • Relative OID: 2.235.1.1.500.11.51.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.8
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 8
  • Description: The PHY bit errors of the link between expander and expander increased too fast. (Cleared)

hwExpanderLowerVoltage

  • Relative OID: 2.235.1.1.500.11.51.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.9
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 9
  • Description: The power of Expander board undervoltage major alarm. (Generated)

hwExpanderLowerVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.51.10
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.10
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 10
  • Description: The power of Expander board undervoltage major alarm. (Cleared)

hwExpanderOverVoltage

  • Relative OID: 2.235.1.1.500.11.51.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 11
  • Description: The power of Expander board overvoltage major alarm. (Generated)

hwExpanderOverVoltageDeassert

  • Relative OID: 2.235.1.1.500.11.51.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.12
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 12
  • Description: The power of Expander board overvoltage major alarm. (Cleared)

hwExpanderVoltageFault

  • Relative OID: 2.235.1.1.500.11.51.13
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.13
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 13
  • Description: Failed to read Expander board voltage. (Generated)

hwExpanderVoltageFaultDeassert

  • Relative OID: 2.235.1.1.500.11.51.14
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.14
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 14
  • Description: Failed to read Expander board voltage. (Cleared)

hwExpanderHeartbeatAbnormal

  • Relative OID: 2.235.1.1.500.11.51.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.15
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 15
  • Description: Expander board heartbeat signal is abnormal. (Generated)

hwExpanderHeartbeatAbnormalDeassert

  • Relative OID: 2.235.1.1.500.11.51.16
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.51.16
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwExpanderEvent 16
  • Description: Expander board heartbeat signal is abnormal. (Cleared)

Back to index