2.235.1.1.500.11.67 hwEIUABoardEvent
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.500.11.67 hwEIUABoardEvent
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
hwEIUABoardEvent - Relative OID:
2.235.1.1.500.11.67 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.67 - Node type: OBJECT IDENTIFIER
- Access: N/A
- Status: -
- MIB definition:
hwServerTRAPObjectV2 67
Object Definitions
Scalar objects and notifications defined under this node.
hwEIUABoardlowerVoltage
- Relative OID:
2.235.1.1.500.11.67.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.67.1 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwEIUABoardEvent 1 - Description: EIUA board voltage below lower major threshold. (Generated)
hwEIUABoardlowerVoltageDeassert
- Relative OID:
2.235.1.1.500.11.67.2 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.67.2 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwEIUABoardEvent 2 - Description: EIUA board voltage below lower major threshold. (Cleared)
hwEIUABoardOverVoltage
- Relative OID:
2.235.1.1.500.11.67.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.67.3 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwEIUABoardEvent 3 - Description: EIUA board overvoltage major alarm. (Generated)
hwEIUABoardOverVoltageDeassert
- Relative OID:
2.235.1.1.500.11.67.4 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.67.4 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwEIUABoardEvent 4 - Description: EIUA board overvoltage major alarm. (Cleared)
hwEIUABoardAccessVoltageFailure
- Relative OID:
2.235.1.1.500.11.67.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.67.5 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwEIUABoardEvent 5 - Description: Failed to read EIUA board voltage. (Generated)
hwEIUABoardAccessVoltageFailureDeassert
- Relative OID:
2.235.1.1.500.11.67.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.500.11.67.6 - Type: NOTIFICATION-TYPE
- Data type:
{ hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId } - Access: notify
- Status: current
- MIB definition:
hwEIUABoardEvent 6 - Description: Failed to read EIUA board voltage. (Cleared)