2.235.1.1.500.10.41 hwBattery
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.500.10.41 hwBattery

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwBattery
  • Relative OID: 2.235.1.1.500.10.41
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.10.41
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObject 41

Object Definitions

Scalar objects and notifications defined under this node.

hwRTCBatterylow

  • Relative OID: 2.235.1.1.500.10.41.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.10.41.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBattery 1
  • Description: RTC battery or RAID card BBU voltage low

hwRTCBatterylowDeassert

  • Relative OID: 2.235.1.1.500.10.41.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.10.41.2
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBattery 2
  • Description: RTC battery or RAID card BBU voltage low deassert

hwRAIDCardBBUFailed

  • Relative OID: 2.235.1.1.500.10.41.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.10.41.17
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBattery 17
  • Description: RAID card BBU failed

hwRAIDCardBBUFailedDeassert

  • Relative OID: 2.235.1.1.500.10.41.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.10.41.18
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBattery 18
  • Description: RAID card BBU failure deassert

hwRAIDCardBBUPresence

  • Relative OID: 2.235.1.1.500.10.41.33
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.10.41.33
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBattery 33
  • Description: RAID card BBU is present

hwRAIDCardBBUPresenceDeassert

  • Relative OID: 2.235.1.1.500.10.41.34
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.10.41.34
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBattery 34
  • Description: RAID card BBU is absent

Back to index