2.235.1.1.500.11.30 hwBasePlaneEvent
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.500.11.30 hwBasePlaneEvent

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: hwBasePlaneEvent
  • Relative OID: 2.235.1.1.500.11.30
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: hwServerTRAPObjectV2 30

Object Definitions

Scalar objects and notifications defined under this node.

hwBasePlaneNotInstalled

  • Relative OID: 2.235.1.1.500.11.30.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.1
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 1
  • Description: Base module not installed.

hwBasePlanePowerOff

  • Relative OID: 2.235.1.1.500.11.30.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.3
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 3
  • Description: Base module installed but powered off.

hwBasePlanePowerOnReq

  • Relative OID: 2.235.1.1.500.11.30.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.5
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 5
  • Description: Base module requesting power-on.

hwBasePlaneBeingPowerOn

  • Relative OID: 2.235.1.1.500.11.30.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.7
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 7
  • Description: Base module in power-on process.

hwBasePlanePoweredOn

  • Relative OID: 2.235.1.1.500.11.30.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.9
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 9
  • Description: Base module powered on.

hwBasePlanePowerOffReq

  • Relative OID: 2.235.1.1.500.11.30.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.11
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 11
  • Description: Base module requesting power-off.

hwBasePlaneBeingPowerOff

  • Relative OID: 2.235.1.1.500.11.30.13
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.13
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 13
  • Description: Base module in power-off process.

hwBasePlaneLSWFault

  • Relative OID: 2.235.1.1.500.11.30.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.17
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 17
  • Description: Base module service LSW fault. (Generated)

hwBasePlaneLSWFaultDeassert

  • Relative OID: 2.235.1.1.500.11.30.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.18
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 18
  • Description: Base module service LSW fault. (Cleared)

hwBasePlaneLSWOverTempMinor

  • Relative OID: 2.235.1.1.500.11.30.19
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.19
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 19
  • Description: Base plane LSW overheating minor alarm. (Generated)

hwBasePlaneLSWOverTempMinorDeassert

  • Relative OID: 2.235.1.1.500.11.30.20
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.20
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 20
  • Description: Base plane LSW overheating minor alarm. (Cleared)

hwBasePlaneLSWOverTempMajor

  • Relative OID: 2.235.1.1.500.11.30.21
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.21
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 21
  • Description: Base plane LSW overheating major alarm. (Generated)

hwBasePlaneLSWOverTempMajorDeassert

  • Relative OID: 2.235.1.1.500.11.30.22
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.22
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 22
  • Description: Base plane LSW overheating major alarm. (Cleared)

hwBasePlaneLSWAccessTempFailure

  • Relative OID: 2.235.1.1.500.11.30.23
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.23
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 23
  • Description: Failed to read Base plane LSW temperature. (Generated)

hwBasePlaneLSWAccessTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.30.24
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.24
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 24
  • Description: Failed to read Base plane LSW temperature. (Cleared)

hwBasePlaneLSWLowerVoltMajor

  • Relative OID: 2.235.1.1.500.11.30.25
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.25
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 25
  • Description: Base plane switch voltage below lower major threshold. (Generated)

hwBasePlaneLSWLowerVoltMajorDeassert

  • Relative OID: 2.235.1.1.500.11.30.26
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.26
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 26
  • Description: Base plane switch voltage below lower major threshold. (Cleared)

hwBasePlaneLSWOverVoltMajor

  • Relative OID: 2.235.1.1.500.11.30.27
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.27
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 27
  • Description: Base plane switch overvoltage major alarm. (Generated)

hwBasePlaneLSWOverVoltMajorDeassert

  • Relative OID: 2.235.1.1.500.11.30.28
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.28
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 28
  • Description: Base plane switch overvoltage major alarm. (Cleared)

hwBasePlaneLSWAccessVoltFailure

  • Relative OID: 2.235.1.1.500.11.30.29
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.29
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 29
  • Description: Failed to read Base plane switch voltage. (Generated)

hwBasePlaneLSWAccessVoltFailureDeassert

  • Relative OID: 2.235.1.1.500.11.30.30
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.30
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 30
  • Description: Failed to read Base plane switch voltage. (Cleared)

hwBasePlaneCPULowerVoltMajor

  • Relative OID: 2.235.1.1.500.11.30.31
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.31
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 31
  • Description: Base plane CPU voltage below lower major threshold. (Generated)

hwBasePlaneCPULowerVoltMajorDeassert

  • Relative OID: 2.235.1.1.500.11.30.32
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.32
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 32
  • Description: Base plane CPU voltage below lower major threshold. (Cleared)

hwBasePlaneCPUOverVoltMajor

  • Relative OID: 2.235.1.1.500.11.30.33
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.33
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 33
  • Description: Base plane CPU overvoltage major alarm. (Generated)

hwBasePlaneCPUOverVoltMajorDeassert

  • Relative OID: 2.235.1.1.500.11.30.34
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.34
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 34
  • Description: Base plane CPU overvoltage major alarm. (Cleared)

hwBasePlaneCPUAccessVoltFailure

  • Relative OID: 2.235.1.1.500.11.30.35
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.35
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 35
  • Description: Failed to read Base plane CPU voltage. (Generated)

hwBasePlaneCPUAccessVoltFailureDeassert

  • Relative OID: 2.235.1.1.500.11.30.36
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.36
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 36
  • Description: Failed to read Base plane CPU voltage. (Cleared)

hwBasePlaneCPUOverTempMinor

  • Relative OID: 2.235.1.1.500.11.30.37
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.37
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 37
  • Description: Base plane CPU overheating minor alarm. (Generated)

hwBasePlaneCPUOverTempMinorDeassert

  • Relative OID: 2.235.1.1.500.11.30.38
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.38
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 38
  • Description: Base plane CPU overheating minor alarm. (Cleared)

hwBasePlaneCPUOverTempMajor

  • Relative OID: 2.235.1.1.500.11.30.39
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.39
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 39
  • Description: Base plane CPU overheating major alarm. (Generated)

hwBasePlaneCPUOverTempMajorDeassert

  • Relative OID: 2.235.1.1.500.11.30.40
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.40
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 40
  • Description: Base plane CPU overheating major alarm. (Cleared)

hwBasePlaneCPUAccessTempFailure

  • Relative OID: 2.235.1.1.500.11.30.41
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.41
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 41
  • Description: Failed to read Base plane CPU temperature. (Generated)

hwBasePlaneCPUAccessTempFailureDeassert

  • Relative OID: 2.235.1.1.500.11.30.42
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.42
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 42
  • Description: Failed to read Base plane CPU temperature. (Cleared)

hwBasePlanePSFault

  • Relative OID: 2.235.1.1.500.11.30.43
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.43
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 43
  • Description: Base plane PS fault. (Generated)

hwBasePlanePSFaultDeassert

  • Relative OID: 2.235.1.1.500.11.30.44
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.44
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 44
  • Description: Base plane PS fault. (Cleared)

hwBasePlaneRestart

  • Relative OID: 2.235.1.1.500.11.30.45
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.500.11.30.45
  • Type: NOTIFICATION-TYPE
  • Data type: { hwTrapSeq, hwTrapSensorName, hwTrapEvent, hwTrapSeverity, hwTrapEventCode, hwTrapEventData2, hwTrapEventData3, hwTrapServerIdentity, hwTrapLocation, hwTrapTime, hwTrapSystemId }
  • Access: notify
  • Status: current
  • MIB definition: hwBasePlaneEvent 45
  • Description: Fabric plane Restart.

Back to index