2.235.1.1.26.50.1 temperatureDescriptionEntry
更新时间: 2026/06/18
在Gitcode上查看源码2.235.1.1.26.50.1 temperatureDescriptionEntry
Revision History
| openUBMC Version | Revision Date | Revision Content |
|---|---|---|
| 26.06 | 2026/06/18 | Auto-generated SNMP branch documentation |
Node Overview
- MIB module: OPENUBMC-SERVER-MIB
- Node name:
temperatureDescriptionEntry - Relative OID:
2.235.1.1.26.50.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1 - Node type: OBJECT-TYPE
- Access: not-accessible
- Status: current
- MIB definition:
temperatureDescriptionTable 1
Description
Information about temperature.
Object Definitions
Scalar objects and notifications defined under this node.
temperatureIndex
- Relative OID:
2.235.1.1.26.50.1.1 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.1 - Type: OBJECT-TYPE
- Data type:
INTEGER(1..766) - Access: not-accessible
- Status: current
- MIB definition:
temperatureDescriptionEntry 1 - Description: Information about temperature index.
temperatureObject
- Relative OID:
2.235.1.1.26.50.1.2 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.2 - Type: OBJECT-TYPE
- Data type:
DisplayString - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 2 - Description: Information about temperature object.
temperatureReading
- Relative OID:
2.235.1.1.26.50.1.3 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.3 - Type: OBJECT-TYPE
- Data type:
INTEGER - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 3 - Description: Information about temperature reading,the unit is 1/10 Celsius degree. If power off, the CPU temperature cannot be readable and is set to 65535.
temperatureUpperNonRecoverable
- Relative OID:
2.235.1.1.26.50.1.4 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.4 - Type: OBJECT-TYPE
- Data type:
INTEGER - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 4 - Description: Information about temperature upper nonrecoverable threshold,the unit is 1/10 Celsius degree,65535 represent NA.
temperatureUpperCritical
- Relative OID:
2.235.1.1.26.50.1.5 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.5 - Type: OBJECT-TYPE
- Data type:
INTEGER - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 5 - Description: Information about temperature upper critical threshold,the unit is 1/10 Celsius degree,65535 represent NA.
temperatureUpperMinor
- Relative OID:
2.235.1.1.26.50.1.6 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.6 - Type: OBJECT-TYPE
- Data type:
INTEGER - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 6 - Description: Information about temperature upper minor threshold,the unit is 1/10 Celsius degree,65535 represent NA.
temperatureLowerNonRecoverable
- Relative OID:
2.235.1.1.26.50.1.7 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.7 - Type: OBJECT-TYPE
- Data type:
INTEGER - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 7 - Description: Information about temperature lower nonrecoverable threshold,the unit is 1/10 Celsius degree,65535 represent NA.
temperatureLowerCritical
- Relative OID:
2.235.1.1.26.50.1.8 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.8 - Type: OBJECT-TYPE
- Data type:
INTEGER - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 8 - Description: Information about temperature lower critical threshold,the unit is 1/10 Celsius degree,65535 represent NA.
temperatureLowerMinor
- Relative OID:
2.235.1.1.26.50.1.9 - Full OID:
1.3.6.1.4.1.2011.2.235.1.1.26.50.1.9 - Type: OBJECT-TYPE
- Data type:
INTEGER - Access: read-only
- Status: current
- MIB definition:
temperatureDescriptionEntry 9 - Description: Information about temperature lower minor threshold,the unit is 1/10 Celsius degree,65535 represent NA.