2.235.1.1.1 system
更新时间: 2026/06/18
在Gitcode上查看源码

2.235.1.1.1 system

Revision History

openUBMC VersionRevision DateRevision Content
26.062026/06/18Auto-generated SNMP branch documentation

Node Overview

  • MIB module: OPENUBMC-SERVER-MIB
  • Node name: system
  • Relative OID: 2.235.1.1.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1
  • Node type: OBJECT IDENTIFIER
  • Access: N/A
  • Status: -
  • MIB definition: openUBMC 1

Child Nodes

Follow the SNMP OID topology; click a row to open the next level.

Relative OIDNode nameTypeDocument
2.235.1.1.1.50systemHealthEventDescriptionTableOBJECT-TYPEsystemHealthEventDescriptionTable

Object Definitions

Scalar objects and notifications defined under this node.

systemHealth

  • Relative OID: 2.235.1.1.1.1
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.1
  • Type: OBJECT-TYPE
  • Data type: INTEGER { ok(1), minor(2), major(3), critical(4) }
  • Access: read-only
  • Status: current
  • MIB definition: system 1
  • Description: systemHealth information about system present state of health. This value will be one of the following: (1-OK, 2-Minor, 3-Major, 4-Critical)

systemBootsequence

  • Relative OID: 2.235.1.1.1.2
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.2
  • Type: OBJECT-TYPE
  • Data type: INTEGER { noOverride(1), pxe(2), hdd(3), cdDvd(4), floppyPrimaryRemovableMedia(5), unspecified(6), biossetup(7) }
  • Access: read-write
  • Status: current
  • MIB definition: system 2
  • Description: Decide the system's first boot device. 1 - No override 2 - Force PXE 3 - Force boot from default Hard-drive 4 - Force boot from default CD/DVD 5 - Force boot from Floppy/primary removable media 6 - boot flags valid. The bit should be set to indicate that valid flag data is present. This bit may be automatically cleared based on the boot flag valid bit clearing parameter, above.(This option is read-only.) 7 - Force boot into BIOS SETUP The default value is 6 (unspecified)

systemTime

  • Relative OID: 2.235.1.1.1.3
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.3
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-only
  • Status: current
  • MIB definition: system 3
  • Description: systemTime information about openUBMC system time, based on UTC. the value such as (yyyy-mm-dd hh:mm:ss).

systemTimeZone

  • Relative OID: 2.235.1.1.1.4
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.4
  • Type: OBJECT-TYPE
  • Data type: Integer32 (-720..840)
  • Access: read-write
  • Status: current
  • MIB definition: system 4
  • Description: systemTimeZone information about openUBMC time zone. The value is in [-720, 840].

safepowerofftime

  • Relative OID: 2.235.1.1.1.5
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.5
  • Type: OBJECT-TYPE
  • Data type: Integer32
  • Access: read-write
  • Status: current
  • MIB definition: system 5
  • Description: The system safe poweroff time, the value 0 indicates non-timeout.

deviceName

  • Relative OID: 2.235.1.1.1.6
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.6
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-only
  • Status: current
  • MIB definition: system 6
  • Description: The device name value between 1 to 63 characters.

deviceSerialNo

  • Relative OID: 2.235.1.1.1.7
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.7
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-only
  • Status: current
  • MIB definition: system 7
  • Description: The device serial number value between 1 to 63 characters.

powerOnPolicy

  • Relative OID: 2.235.1.1.1.8
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.8
  • Type: OBJECT-TYPE
  • Data type: INTEGER { stayoff(1), restorePreviousState(2), turnon(3) }
  • Access: read-write
  • Status: current
  • MIB definition: system 8
  • Description: 1 - Stay Off 2 - Restore Previous State 3 - Turn On Default value is turnon(3).

hostName

  • Relative OID: 2.235.1.1.1.9
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.9
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-write
  • Status: current
  • MIB definition: system 9
  • Description: The host name between 1 to 64 characters. Supported characters: 0-9 a-z A-Z - ('-' is not allowed to be the first/last character).

systemGuid

  • Relative OID: 2.235.1.1.1.10
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.10
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-only
  • Status: current
  • MIB definition: system 10
  • Description: The GUID is hex string such as ----.

identify

  • Relative OID: 2.235.1.1.1.11
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.11
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-write
  • Status: current
  • MIB definition: system 11
  • Description: identify use to control on or off of led. identify mode: 0 - Off 1 - Temporary On 2 - Force Identify On set format: <mode>,[ontime] get format: <mode> When <mode> = 0 or <mode> = 2, the format is only <mode>. [ontime] is option and value is in [1,255], When set Temporary On without [ontime], The default Temporary On time are 15 seconds.

systemPowerState

  • Relative OID: 2.235.1.1.1.12
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.12
  • Type: OBJECT-TYPE
  • Data type: INTEGER { normalPowerOff(1), powerOn(2), forcedSystemReset(3), forcedPowerCycle(4), forcedPowerOff(5) }
  • Access: read-write
  • Status: current
  • MIB definition: system 12
  • Description: System Power Status Get. 1 - Power Off 2 - Power On System Power Status Set. 1 - Normal Power Off 2 - Power On 3 - Forced System Reset 4 - Forced Power Cycle 5 - Forced Power Off The set actions are a process which will take effect in a while. When system in poweroff state, Power Off/Reset/PowerOffThenOn commonds are not supported.

deviceOwnerID

  • Relative OID: 2.235.1.1.1.14
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.14
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-only
  • Status: current
  • MIB definition: system 14
  • Description: The device owner ID, maxlength is 64 characters.

deviceslotID

  • Relative OID: 2.235.1.1.1.15
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.15
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-only
  • Status: current
  • MIB definition: system 15
  • Description: The device slot ID of a server exists, the value ranges from 1 to 80. Otherwise, the value is 0.

remoteOEMInfo

  • Relative OID: 2.235.1.1.1.16
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.16
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-write
  • Status: current
  • MIB definition: system 16
  • Description: The remoteOEMinfo, maxlength is 255 characters.

deviceLocationInfo

  • Relative OID: 2.235.1.1.1.17
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.17
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-write
  • Status: current
  • MIB definition: system 17
  • Description: The deviceLocationInfo between 0 and 64 characters. Default value is server room.

deviceRemoteManageID

  • Relative OID: 2.235.1.1.1.18
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.18
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-write
  • Status: current
  • MIB definition: system 18
  • Description: The deviceRemoteManageID between 0 and 64 characters.

bmcReboot

  • Relative OID: 2.235.1.1.1.19
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.19
  • Type: OBJECT-TYPE
  • Data type: INTEGER { reboot(1) }
  • Access: read-write
  • Status: current
  • MIB definition: system 19
  • Description: Reboot the BMC management system.When set, the value is only 1, write only.

powerOnPermit

  • Relative OID: 2.235.1.1.1.20
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.20
  • Type: OBJECT-TYPE
  • Data type: INTEGER { notPermit(1), permit(2) }
  • Access: read-write
  • Status: current
  • MIB definition: system 20
  • Description: Set power on permission. notPermit 1, permit 2.

autoDiscoveryEnable

  • Relative OID: 2.235.1.1.1.21
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.21
  • Type: OBJECT-TYPE
  • Data type: INTEGER { disable(1), enable(2) }
  • Access: read-write
  • Status: current
  • MIB definition: system 21
  • Description: Auto discovery state. disable 1, enable 2. Default value is disable(1).

productUniqueID

  • Relative OID: 2.235.1.1.1.22
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.22
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-only
  • Status: current
  • MIB definition: system 22
  • Description: The productUniqueID is hex string.

systemCpuUsage

  • Relative OID: 2.235.1.1.1.23
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.23
  • Type: OBJECT-TYPE
  • Data type: INTEGER
  • Access: read-only
  • Status: current
  • MIB definition: system 23
  • Description: Percent of CPU usage. The value defined as: -1: invalid current CPU usage. [0,100]: represents the current CPU usage. NOTE: If BMA 2.0 has been installed and started on the OS, BMA 2.0 provides the CPU usage data, which is consistent with that collected by the OS. If BMA 2.0 is not installed or started, the Intel management Engine (ME) provides the CPU usage data, which is compute utilization per second of all cores calculated by CPU internal modules.

systemBootOnce

  • Relative OID: 2.235.1.1.1.24
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.24
  • Type: OBJECT-TYPE
  • Data type: INTEGER { once(1), permanent(2) }
  • Access: read-write
  • Status: current
  • MIB definition: system 24
  • Description: System boot once or permanent. once 1, permanent 2. Default value is once(1).

systemMemUsage

  • Relative OID: 2.235.1.1.1.25
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.25
  • Type: OBJECT-TYPE
  • Data type: INTEGER
  • Access: read-only
  • Status: current
  • MIB definition: system 25
  • Description: Percent of memory usage. The value defined as: -1: invalid current memory usage. [0,100]: represents the current memory usage. NOTE: If BMA 2.0 has been installed and started on the OS, BMA 2.0 provides the memory usage data, which is consistent with that collected by the OS. If BMA 2.0 is not installed or started, the Intel management Engine (ME) provides the memory bandwidth usage, which is different from the memory usage collected by the OS.

systemCpuUsageThre

  • Relative OID: 2.235.1.1.1.26
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.26
  • Type: OBJECT-TYPE
  • Data type: INTEGER
  • Access: read-write
  • Status: current
  • MIB definition: system 26
  • Description: Percent of CPU usage threshold. This value is in [0,100].

systemMemUsageThre

  • Relative OID: 2.235.1.1.1.27
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.27
  • Type: OBJECT-TYPE
  • Data type: INTEGER
  • Access: read-write
  • Status: current
  • MIB definition: system 27
  • Description: Percent of memory usage threshold. This value is in [0,100].

systemDiskPartitionUsageThre

  • Relative OID: 2.235.1.1.1.28
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.28
  • Type: OBJECT-TYPE
  • Data type: INTEGER
  • Access: read-write
  • Status: current
  • MIB definition: system 28
  • Description: Percent of hard disk partition usage threshold. This value is in [0,100].

systemTimeZoneStr

  • Relative OID: 2.235.1.1.1.29
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.29
  • Type: OBJECT-TYPE
  • Data type: DisplayString
  • Access: read-write
  • Status: current
  • MIB definition: system 29
  • Description: systemTimeZone information about openUBMC time zone. The value can be time-offset : GMT-12:00~GMT+14:00 e.g. GMT+08:00,GMT-04:30. The value can be city name , e.g. Asia/Shanghai,America/New_York.

systemLeakStrategy

  • Relative OID: 2.235.1.1.1.30
  • Full OID: 1.3.6.1.4.1.2011.2.235.1.1.1.30
  • Type: OBJECT-TYPE
  • Data type: INTEGER { manualpoweroff(1), autopoweroff(2) }
  • Access: read-write
  • Status: current
  • MIB definition: system 30
  • Description: 1 - Manual Power Off 2 - Auto Power Off 255 - Invalid value Default value is 1.

Back to index