Set Sensor Hysteresis
更新时间: 2026/08/06
在Gitcode上查看源码

Set Sensor Hysteresis

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Sets the sensor hysteresis.

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFnS/E 04h
CMD24h
1sensor number (FFh=reserved)
2reserved for future 'hysteresis mask' definition. Write as 'FFh'
3Positive-going Threshold Hysteresis Value. Set to 00h if sensor does not
support positive-going threshold hysteresis. This value is subtracted from
positive going thresholds to determine the point where the asserted status for that threshold will clear.
4Negative-going Threshold Hysteresis Value. This value is added to negative
going thresholds to determine the point where the asserted status for that
threshold will clear. Set to 00h if sensor does not support negative-going
threshold hysteresis.

Response Information

ByteData Field
1Completion Code

Command Example

Set the hysteresis of a sensor.

Request:

bash
ipmicmd -k "0f 00 04 24 01 ff 03 03" smi 0

Response:

text
0f

Back to Index