Get PEF Capabilities
更新时间: 2025/06/26
在Gitcode上查看源码10h — Get PEF Capabilities
Change History
| openUBMC Version | Revision Date | Author | Description |
|---|---|---|---|
| 25.06 | 2025/06/26 | pengqiang-gs | Initial draft, add command details |
Basic Information
Function Description
Queries the properties of the PEF implementation on the BMC.
Privilege
ReadOnly
Command Information
Request Information
No request data.
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | PEF Version (BCD encoded, LSN first, 51h for this specification. 51h = version 1.5) |
| 3 | [7] - 1b = OEM Event Record Filtering supported [6] - reserved Action Support [5] - 1b = diagnostic interrupt [4] - 1b = OEM action [3] - 1b = power cycle [2] - 1b = reset [1] - 1b = power down [0] - 1b = Alert |
| 4 | Number of event filter table entries (1 based) |
Command Examples
Example 1: Send Platform Event
- Request:
- Response: