Function Description
Queries the self-check result.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | PICMG 2Ch |
| CMD | 36h |
| 1 | Set PICMG ID to 0. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code 0: The self-check is complete. For the self-test result, see the Self-test Result 1 and Self-test Result 2 fields in the response. 80h=The self-check is in progress. Run the Query self-test results command to query the progress of the self-check. 81h=The current interface does not support software upgrade. The remaining response bytes are valid. D5h=No self-check is performed and no self-check result is available. The Self-test Result 1 and Self-test Result 2 fields are not displayed. |
| 2 | Set PICMG ID to 0. |
| 3 | Self-test Result 1 55h=No error. The self-check is passed. 56h=Reserved 57h=The data or device cannot be accessed or is damaged. 58h: fatal hardware error (The system considers that the IPMC cannot work.) This indicates that the hardware, sensor, or memory needs to be replaced or repaired. 60h=The component is faulty. FFh=Reserved Other values are related to the device. For details, see the specific device specifications. |
| 4 | Self-test Result 2 If Self-test Result 1 is 55h or FFh, set this parameter to 0. If the value of Self-test Result 1 is 57h, 1b indicates that the test fails, and 0 indicates that the test result is unknown. [7] 1=The SEL device cannot be accessed. [6] 1=The SDR storage device cannot be accessed. [5] 1=Failed to access the BMC FRU device. [4] 1=The IPMB signal cable does not respond. [3] 1: The SDR memory is empty. [2] 1=The internal use area of the FRU is damaged. [1] 1=The boot block software of the controller is damaged. [0] 1=The controller software is damaged. If the value of Self-test Result 1 is 58h, this field is reserved. If the value of Self-test Result 1 is 60h, the component test fails. Other values of Self-test Result 1 are reserved. |
Command Example
Query the self-check result.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN