Activate firmware ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Activate the firmware.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFnPICMG 2Ch
CMD35h
1PICMG ID. Enter 0.
(2)Rollback Override Policy: This field is optional.
0: Automatic rollback is allowed.
1: The automatic rollback is overridden.
This setting prevents the IPMC from automatically rolling back until the next software activation.

Response Information ​

ByteData Field
1Completion Code
80h=The command is being executed. Run the Get upgrade status command to query the command execution progress.
D5h=The software has been activated.
2PICMG ID. Enter 0.

Command Example ​

Activate the firmware. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​