Renegotiate Power ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Re-negotiate power information.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFnPICMG 2Ch
CMD13h
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.
(2)Requesting FRU Device ID. This byte is optional. If this is present, it designates which FRU Device ID wishes to have power levels renegotiated. If this byte is not present, the Shelf Manager renegotiates with all FRUs under the requesting IPM Controller.

Response Information ​

ByteData Field
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.

Command Example ​

Renegotiate power information. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​