代码仓
中
Compute Power Properties
更新时间: 2026/08/06
在AtomGit上查看源码

Compute Power Properties ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Calculates the power attribute.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFnPICMG 2Ch
CMD10h
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used
2FRU Device ID. Indicates an individual FRU device to lock in the power properties

Response Information ​

ByteData Field
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used
3Number of Spanned Slots. Indicates the total number of Slots spanned by the Board. This is 1 for a Board that inserts into a single Slot and any non-Board FRU
4IPM Controller Location. When a Board spans more than one Slot (a multi-Slot Board), the Shelf Manager needs to know which Slot contains the IPM Controller. This number treats the left most Slot location of the multi-Slot Board as 0 and increment by single units moving to the right.
This value is 0 for a Board that inserts into a single Slot and any non- Board FRU. This value represents the location of the Zone 1 connection for the Board

Command Example ​

Calculate the power attribute. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​