代码仓
中
Set FRU Activation
更新时间: 2026/08/06
在AtomGit上查看源码

Set FRU Activation ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Activates the FRU.

Privilege ​

PowerMgnt

Command Information ​

Request Information ​

ByteData Field
NetFnPICMG 2Ch
CMD0Ch
1PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.
2FRU Device ID
3FRU Activation/Deactivation
00h=Deactivate FRU
01h=Activate FRU
02h-FFh=Reserved

Response Information ​

ByteData Field
1Completion Code
2PICMG Identifier. Indicates that this is a PICMG-defined group extension command. A value of 00h is used.

Command Example ​

Activate an FRU. ​

Request:

bash
ipmicmd -k "0f 00 2c 0c 00 00 01" smi 0

Response:

text
0f 2d 00 0c 00 00