Get FRU LED Properties
更新时间: 2026/08/06
在Gitcode上查看源码

Get FRU LED Properties

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtains FRU LED attributes.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFnPICMG 2Ch
CMD05h
1PICMG Identifier, Indicates that this is a PICMG defined group extension command. A value of 00h is used
2FRU Device ID

Response Information

ByteData Field
1Completion Code
2PICMG Identifier
Indicates that this is a PICMG defined group extension command. A value of 00h is used
3General Status LED Properties
A bit field indicating the FRU's ability to control the four LEDs . When a bit is set, the FRU can control the associated LED
Bit LED Name
[7:4] Reserved, is set to 0.
[3] LED
[2] LED 2
[1] LED 1
[0] BLUE LED
4Application Specific LED Count
The number of application specific LEDs under control of the IPM Controller
00h-FBh Number of application specific LEDs under control by IPM Controller. If no application specific LEDs are present this field is 00h
FCh-FFh Reserved

Command Example

Obtain FRU LED attributes.

Request:

bash
ipmicmd -k "0f 00 2c 05 00 00" smi 0

Response:

text
0f 2d 00 05 00 00 04 01

Back to Index