Function Description

Disable the DPU standby power supply and forcibly power off the host OS.

Privilege

PowerMgnt, administrator permission. After the system is locked, the SET operation is prohibited.

Available only after China Telecom customization is enabled

Command Information

Request Information

ByteData Field
NetFn3Ah
CMDF5h
1Sub command=00h

Response Information

ByteData Field
1Completion Code
0x0: The command is executed successfully.
Other return codes: The command execution is abnormal.

Command Example

Power off the DPU and the server.

Request:

bash
ipmitool raw 0x3a 0xf5 0x00

Response:

text
0x00