To query whether a component supports the upgrade command
更新时间: 2026/08/06
在Gitcode上查看源码To query whether a component supports the upgrade command
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Queries whether the component supports the upgrade command.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | d4h |
| 1:3 | fruId |
| 4 | deviceId |
| 5 | sdrType |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | True/False |
Command Example
Query whether the mainboard BMC supports the upgrade command.
Request:
bash
ipmitool raw 0x32 0xd4 0x00 0x02 0x00 0x00 0x01Response:
text
01