Set Storage Node Auto Power-on Flag After Abnormal Shutdown
更新时间: 2026/08/06
在Gitcode上查看源码

Set Storage Node Auto Power-on Flag After Abnormal Shutdown

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Sets whether to power on a storage node again after it is powered off unexpectedly.

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn32h
CMDbch
1:3fruId
4deviceId
5sdrType 0x58
6:70x76 0x58 A Node Is Not Automatically Powered On After Being Powered Off Unexpectedly
0xcb 0xad Automatic power-on of a node after an unexpected power-off

Response Information

ByteData Field
1Completion Code

Command Example

Disable a storage node from automatically powering on after it is powered off unexpectedly.

Request:

bash
ipmitool raw 0x32 0xbc 0x00 0x02 0x00 0x00 0x58 0x76 0x58

Response:

text

Back to Index