代码仓
中
Set Smartcooling Mode
更新时间: 2026/08/06
在AtomGit上查看源码

Set Smartcooling Mode ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Sets the intelligent heat dissipation mode.

Privilege ​

BasicSetting

Command Information ​

Request Information ​

ByteData Field
NetFn32h
CMDbch
1slot_id: fan slot ID
2:3Set fru_type to 0x0002.
4device_id: Set it to 0.
5sdr_type: 0x42
6smart_mode:
00h: default mode
01h: intelligent noise mode
02h: high-performance temperature control mode
03h: customized mode
04h: smart temperature control mode
05h: intelligent power consumption mode
7smart_mode indicates the user-defined target temperature in user-defined mode.

Response Information ​

ByteData Field
1Completion Code

Command Example ​

Set the intelligent heat dissipation mode. ​

Request:

bash
ipmitool raw 0x32 0xbc 0x00 0x02 0x00 0x00 0x42 0x01 0x00

Response:

text