Clear High Temperature Recovery Auto Power-on Scene Flag
更新时间: 2026/08/06
在Gitcode上查看源码Clear High Temperature Recovery Auto Power-on Scene Flag
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Clears the flag of automatic power-on upon high temperature recovery.
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | bch |
| 1:3 | fru_id: 0x000080 |
| 4 | device_id: 0x00 |
| 5 | sdr_type: 0x9c |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
Command Example
Clear the flag of automatic power-on upon high temperature recovery.
Request:
bash
ipmitool raw 0x32 0xbc 0x00 0x00 0x80 0x00 0x9cResponse:
text