Get Power Supply LoadInfo Type Info
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the power supply type from Loadinfo.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | bbh |
| 1 | slotNum |
| 2:3 | 0x1000 |
| 4 | DeviceId. Set it to 0x00. |
| 5 | 0x59 |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:33 | Power LoadInfo Type |
Command Example
Obtain the load information of the power module in slot 1.
Request:
ipmitool raw 0x32 0xbb 0x01 0x10 0x00 0x00 0x59Response:
30 32 33 31 32 48 47 59 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00