Query FRU Alarm Aggregation
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Querying FRU Alarm Aggregation
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | B3h |
| 1 | The FRU ID starts from 0. |
| 2:3 | Fru type 0x0002: control board 0x0004BBU 0x0001 Interface Card (CST0221V6) 0x0200: fan board |
| 4 | Device id |
| 5 | Sdr type 0x3b: alarm type 0x3c: alarm status |
| 6 | Need num |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:(need_num*4+1) | Alarm state or state |
Command Example
Query the FRU alarm type.
Request:
ipmitool raw 0x32 0xb3 0x00 0x02 0x00 0x00 0x3b 0x30Response:
00 00 00 00 00 00 00 00 1f 00 00 00 1f 00 00 00
3e 00 00 00 3e 00 00 00 3e 00 00 00 3e 00 00 00
00 00 00 00 00 00 00 00 4f 00 00 00 4f 00 00 00
4f 00 00 00 4f 00 00 00 4f 00 00 00 4f 00 00 00
4f 00 00 00 43 00 00 00 43 00 00 00 52 00 00 00
52 00 00 00 4d 00 00 00 27 00 00 00 51 00 00 00
50 00 00 00 50 00 00 00 09 00 00 00 09 00 00 00
09 00 00 00 09 00 00 00 06 00 00 00 06 00 00 00
06 00 00 00 06 00 00 00 06 00 00 00 06 00 00 00
15 00 00 00 15 00 00 00 24 00 00 00 13 00 00 00
29 00 00 00 29 00 00 00 29 00 00 00 29 00 00 00
29 00 00 00 29 00 00 00 29 00 00 00 55 00 00 00