Query FRU Alarm Aggregation
更新时间: 2026/08/06
在Gitcode上查看源码

Query FRU Alarm Aggregation

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Querying FRU Alarm Aggregation

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn32h
CMDB3h
1The FRU ID starts from 0.
2:3Fru type
0x0002: control board
0x0004BBU
0x0001 Interface Card (CST0221V6)
0x0200: fan board
4Device id
5Sdr type
0x3b: alarm type
0x3c: alarm status
6Need num

Response Information

ByteData Field
1Completion Code
2:(need_num*4+1)Alarm state or state

Command Example

Query the FRU alarm type.

Request:

bash
ipmitool raw 0x32 0xb3 0x00 0x02 0x00 0x00 0x3b 0x30

Response:

text
00 00 00 00 00 00 00 00 1f 00 00 00 1f 00 00 00
3e 00 00 00 3e 00 00 00 3e 00 00 00 3e 00 00 00
00 00 00 00 00 00 00 00 4f 00 00 00 4f 00 00 00
4f 00 00 00 4f 00 00 00 4f 00 00 00 4f 00 00 00
4f 00 00 00 43 00 00 00 43 00 00 00 52 00 00 00
52 00 00 00 4d 00 00 00 27 00 00 00 51 00 00 00
50 00 00 00 50 00 00 00 09 00 00 00 09 00 00 00
09 00 00 00 09 00 00 00 06 00 00 00 06 00 00 00
06 00 00 00 06 00 00 00 06 00 00 00 06 00 00 00
15 00 00 00 15 00 00 00 24 00 00 00 13 00 00 00
29 00 00 00 29 00 00 00 29 00 00 00 29 00 00 00
29 00 00 00 29 00 00 00 29 00 00 00 55 00 00 00

Back to Index