Query FRU Alarm Aggregation
更新时间: 2026/08/06
在Gitcode上查看源码Query FRU Alarm Aggregation
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Querying FRU Alarm Aggregation
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | B3h |
| 1 | The FRU ID starts from 0. |
| 2:3 | Fru type 0x0002: control board 0x0004BBU 0x0001 Interface Card (CST0221V6) 0x0200: fan board |
| 4 | Device id |
| 5 | Sdr type 0x3b: alarm type 0x3c: alarm status |
| 6 | Need num |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:(need_num*4+1) | Alarm state or state |
Command Example
Query the FRU alarm type.
Request:
bash
ipmitool raw 0x32 0xb3 0x00 0x02 0x00 0x00 0x3b 0x30Response:
text
00 00 00 00 00 00 00 00 1f 00 00 00 1f 00 00 00
3e 00 00 00 3e 00 00 00 3e 00 00 00 3e 00 00 00
00 00 00 00 00 00 00 00 4f 00 00 00 4f 00 00 00
4f 00 00 00 4f 00 00 00 4f 00 00 00 4f 00 00 00
4f 00 00 00 43 00 00 00 43 00 00 00 52 00 00 00
52 00 00 00 4d 00 00 00 27 00 00 00 51 00 00 00
50 00 00 00 50 00 00 00 09 00 00 00 09 00 00 00
09 00 00 00 09 00 00 00 06 00 00 00 06 00 00 00
06 00 00 00 06 00 00 00 06 00 00 00 06 00 00 00
15 00 00 00 15 00 00 00 24 00 00 00 13 00 00 00
29 00 00 00 29 00 00 00 29 00 00 00 29 00 00 00
29 00 00 00 29 00 00 00 29 00 00 00 55 00 00 00