Obtain the sensor alarm status
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the sensor alarm status.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | B1h |
| 1 | Fru id |
| 2:3 | Fru type 0x0002: control board 0x0004 BBU 0x0001 Interface Card (CST0221V6) |
| 4 | Device id |
| 5 | Sdr type 0x1: temperature 0x2 voltage |
| 6 | Need num |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:(need_num*4+1) | Sensor alarm state |
Command Example
Obtain the sensor alarm status.
Request:
ipmitool raw 0x32 0xb1 0x00 0x02 0x00 0x00 0x01 0x10Response:
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00