Get Board Reset Reason
更新时间: 2026/08/06
在Gitcode上查看源码Get Board Reset Reason
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the cause of the board reset.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 9ah |
| 1:3 | fru_id: 0x000200 |
| 4 | device_id: 0x00 |
| 5 | sdr_type: 0x00 |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | reason: reset reason 0: The entire chip is not reset. 1: The internal software triggers the reset of the entire chip. 2: The internal watchdog triggers the reset of the entire chip. 3: reset triggered by internal emptying timeout 4: reset caused by PAD_RSTN |
Command Example
Obtain the board reset reason.
Request:
bash
ipmitool raw 0x32 0x9a 0x00 0x02 0x00 0x00 0x00Response:
text
01