Get Board Reset Reason
更新时间: 2026/08/06
在Gitcode上查看源码

Get Board Reset Reason

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Obtain the cause of the board reset.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn32h
CMD9ah
1:3fru_id: 0x000200
4device_id: 0x00
5sdr_type: 0x00

Response Information

ByteData Field
1Completion Code
2reason: reset reason
0: The entire chip is not reset.
1: The internal software triggers the reset of the entire chip.
2: The internal watchdog triggers the reset of the entire chip.
3: reset triggered by internal emptying timeout
4: reset caused by PAD_RSTN

Command Example

Obtain the board reset reason.

Request:

bash
ipmitool raw 0x32 0x9a 0x00 0x02 0x00 0x00 0x00

Response:

text
01