Query Device Indicator Status
更新时间: 2026/08/06
在Gitcode上查看源码Query Device Indicator Status
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
This command is used to query the status of the health indicator and location indicator on the controller and enclosure.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 7ah |
| 1 | Reversed |
| 2:5 | Position Subrack: 0x00800000, Controller: 0x02000000, Management board: 0x04000000 |
| 6:9 | LedType Power indicator: 0x00000000, Health indicator: 0x01000000, Location indicator: 0x02000000 |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | LedState Open: 01, Close: 00 |
Command Example
Turn on the health indicator of the controller.
Request:
bash
ipmitool raw 0x32 0x7a 0x00 0x02 0x00 0x00 0x00 0x02 0x00 0x00 0x00Response:
text
01