Query Valid Attribution Info of Management Port IP Configuration
更新时间: 2026/08/06
在Gitcode上查看源码Query Valid Attribution Info of Management Port IP Configuration
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Check whether the IP address configuration of the management network port is valid.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 72h |
| 1:3 | FruId. Set it to 0xff0400. |
| 4 | DeviceId. Set it to 0x00. |
| 5 | 96h |
| 6 | sdrType: 0x00 or 0x01 |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | 00h: The IP configuration information is invalid. 01h: The ownership of the IP configuration information is valid. ffh: indicates the IP address configuration information. |
Command Example
Query the IP address configuration of the management network port.
Request:
bash
ipmitool raw 0x32 0x72 0xff 0x04 0x00 0x00 0x96 0x00Response:
text
ff