Query the Nixie Tube Number System Display
更新时间: 2026/08/06
在Gitcode上查看源码Query the Nixie Tube Number System Display
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Querying the Nixie Tube Number System Display
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 72h |
| 1:3 | FruId. Set it to 0x000080. |
| 4 | DeviceId. Set it to 0x00. |
| 5 | 90h |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2 | 00h: decimal 01h: hexadecimal |
Command Example
Query the hexadecimal display of the nixie tube.
Request:
bash
ipmitool raw 0x32 0x72 0x00 0x00 0x80 0x00 0x90Response:
text
00