Basic Information

Function Description

Setting the Controller BMC to Reset the BootLoad

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn32h
CMD71h
1:3fru_id: 0x000200
4device_id: 0x00
5sdr_type: 0x97
6src_ctrl_id: original address
0x00: controller A; 0x01: controller B
7dst_ctrl_id: destination address
0x00: controller A; 0x01: controller B
8reset_type: reset type
0: warm reset; 1: cold reset

Response Information

ByteData Field
1Completion Code

Command Example

Set the controller BMC to reset the normal system.

Request:

bash
ipmitool raw 0x32 0x71 0x00 0x02 0x00 0x00 0x97 0x00 0x01 0x00

Response:

text