Set Controller BMC Reset Main System
更新时间: 2026/08/06
在Gitcode上查看源码Set Controller BMC Reset Main System
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Setting the Controller BMC to Reset the BootLoad
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 71h |
| 1:3 | fru_id: 0x000200 |
| 4 | device_id: 0x00 |
| 5 | sdr_type: 0x97 |
| 6 | src_ctrl_id: original address 0x00: controller A; 0x01: controller B |
| 7 | dst_ctrl_id: destination address 0x00: controller A; 0x01: controller B |
| 8 | reset_type: reset type 0: warm reset; 1: cold reset |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
Command Example
Set the controller BMC to reset the normal system.
Request:
bash
ipmitool raw 0x32 0x71 0x00 0x02 0x00 0x00 0x97 0x00 0x01 0x00Response:
text