Set the Nixie Tube to Display the Frame Number
更新时间: 2026/08/06
在Gitcode上查看源码Set the Nixie Tube to Display the Frame Number
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Set the frame number information to the nixie tube.
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 69h |
| 1:3 | FruId. Set it to 0x000080. |
| 4 | DeviceId. Set it to 0x00. |
| 5 | SdrType. Set it to 0x00. |
| 6:7 | frameLedNum (LS Byte first) |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
Command Example
Set the subrack ID displayed on the LED to 5.
Request:
bash
ipmitool raw 0x32 0x69 0x00 0x00 0x80 0x00 0x00 0x05 0x00Response:
text