Get Pangea Interface Card Name
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtaining the Fru Name of a Pangea Interface Module
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 60h |
| 1 | slot_num |
| 2 | 0x01 |
| 3:4 | Fill in all 0s. |
| 5 | Sdrtype. Set it to 0x54. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:33 | FruName |
Command Example
Obtain the name of the Pangea interface module in slot 1.
Request:
ipmitool raw 0x32 0x60 0x01 0x01 0x00 0x00 0x54Response:
02 01 01 02 65 02 03 05 01 05 01 02 03 04 05 01
21 01 01 02 65 02 03 05 01 05 01 02 03 04 05 01