Set Device Indicator Status
更新时间: 2026/08/06
在Gitcode上查看源码

Set Device Indicator Status

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

You can turn on or off the health indicator and location indicator on the controller and enclosure.

Privilege

BasicSetting

Command Information

Request Information

ByteData Field
NetFn32h
CMD4ch
1Reversed
2:5Position
Subrack: 0x00800000,
Controller: 0x02000000,
Management board: 0x04000000
6:9LedType
Power indicator: 0x00000000,
Health indicator: 0x01000000,
Location indicator: 0x02000000
10:13LedState
Run the 0x01000000 command to enable the function,
Disable: 0x00000000

Response Information

ByteData Field
1Completion Code

Command Example

Turn on the health indicator of the controller.

Request:

bash
ipmitool raw 0x32 0x4c 0x00 0x02 0x00 0x00 0x00 0x02 0x00 0x00 0x00 0x01 0x00 0x00 0x00

Response:

text

Back to Index