Send power-off command
更新时间: 2026/08/06
在Gitcode上查看源码Send power-off command
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Send a power-off command.
Privilege
BasicSetting
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 4bh |
| 1:3 | fruId |
| 4 | deviceId |
| 5 | sdrType |
| 6 | powerCtrlMode indicates normal or abnormal power-off. 0: The board is powered off normally. 1: The board is powered off abnormally. 2: The system (enclosure) is powered off normally. 3: The system (enclosure) is powered off abnormally. Other values: reserved |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
Command Example
Power off a board.
Request:
bash
ipmitool raw 0x32 0x4b 0x00 0x02 0x00 0x00 0x01 0x00Response:
text