Basic Information

Function Description

Obtains the BBU service life pre-expiration alarm threshold.

Privilege

ReadOnly

Command Information

Request Information

ByteData Field
NetFn32h
CMD45h
1:3fru_id: 0x002000
4Device_id. Set this parameter to 0x00.
5sdr_type: 0x27

Response Information

ByteData Field
1Completion Code
2:3bbu_prealarm_threshold: pre-expiration time alarm threshold (month)

Command Example

Obtain the alarm threshold for the BBU service life.

Request:

bash
ipmitool raw 0x32 0x45 0x00 0x20 0x00 0x00 0x27

Response:

text
5d 00