Get BBU Life Pre-expiration Time Alarm Threshold
更新时间: 2026/08/06
在Gitcode上查看源码Get BBU Life Pre-expiration Time Alarm Threshold
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the BBU service life pre-expiration alarm threshold.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 45h |
| 1:3 | fru_id: 0x002000 |
| 4 | Device_id. Set this parameter to 0x00. |
| 5 | sdr_type: 0x27 |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:3 | bbu_prealarm_threshold: pre-expiration time alarm threshold (month) |
Command Example
Obtain the alarm threshold for the BBU service life.
Request:
bash
ipmitool raw 0x32 0x45 0x00 0x20 0x00 0x00 0x27Response:
text
5d 00