Get Power Supply 32-bit Alarm Code
更新时间: 2026/08/06
在Gitcode上查看源码Get Power Supply 32-bit Alarm Code
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtain the 32-bit alarm code of the power supply.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 33h |
| 1 | slotNum |
| 2:3 | 0x1000 |
| 4 | DeviceId. Set it to 0x00. |
| 5 | SdrType. Set it to 0x00. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:5 | Power 32Bit AlarmCode |
Command Example
Obtain the 32-bit alarm code of the power module in slot 1.
Request:
bash
ipmitool raw 0x32 0x33 0x01 0x10 0x00 0x00 0x00Response:
text
00 00 00 00