Get Power Supply Product SN
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtaining the Power Product Serial Number
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 32h |
| CMD | 2dh |
| 1 | slotNum |
| 2:3 | 0x1000 |
| 4 | DeviceId. Set it to 0x00. |
| 5 | SdrType. Set it to 0x00. |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:33 | SerialNumber |
Command Example
Obtain the serial number of the power module in slot 1.
Request:
ipmitool raw 0x32 0x2d 0x01 0x10 0x00 0x00 0x00Response:
32 31 30 32 33 31 32 59 4b 52 4c 55 50 41 30 30 34 33 35 33 00 00 00 00 00 00 00 00 00 00 00 00