Port Loop Test
更新时间: 2026/08/06
在Gitcode上查看源码

Port Loop Test

Change History

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information

Function Description

Performs a loop test on a port.

Privilege

Command Information

Request Information

ByteData Field
NetFn30h
CMDb0h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command = F0h
5Fun ID=0x02
600h : start
01h : get test result
7test time

Response Information

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
5:8Test Progress
9:12Error packet

Command Example

Clear the electronic label.

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index