代码仓
中
Set Lpar DFT config
更新时间: 2026/08/06
在AtomGit上查看源码

Set Lpar DFT config ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Sets the Lpar DFT configuration.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD97h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command. The sub command is 0eh.
5Configuration Type
00h=Logical Partition Boot Option
01h=Equipment mode
6:NConfiguration parameter data. For details, see Table 1.

Response Information ​

ByteData Field
1Completion Code
80h=parameter not supported.
81h=attempt to set the 'set in progress' value (in parameter #0) when not in the 'set complete' state. (This completion code provides a way to recognize that another party has already 'claimed' the parameters)
82h=attempt to write read-only parameter
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Reference Information ​

Table 1 set Lpar dft config response

ParameterParameter Dataconfiguration type
lpar setup configwrite-only00h Logical partition startup shutdown
01h: logical partition startup enabled
0
lpar dft mode configwrite-only00h: The equipment mode is disabled.
01h: The equipment mode is enabled.
1

Command Example ​

Set the Lpar DFT configuration. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​