Get Lpar DFT config
更新时间: 2026/08/06
在Gitcode上查看源码Get Lpar DFT config
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Obtains the Lpar DFT configuration.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 97h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command = 0dh |
| 5 | Configuration type 00h=Logical Partition Boot Option 01h=Equipment mode |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code Generic codes, plus following command-specific completion code(s): 80h=parameter not supported 83h=no more data |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 5:N | Configuration parameter data. For details, see Table 1. |
Reference
Table 1 get Lpar dft config response
| Parameter | Configuration parameter data | configuration type | |
|---|---|---|---|
| lpar setup status | read-only | 00h Logical partition startup shutdown 01h: logical partition startup enabled | 0 |
| lpar dft mode | read-only | 00h: The equipment mode is disabled. 01h: The equipment mode is enabled. | 1 |
Command Example
Obtain the Lpar DFT configuration.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN