Function Description
Configure the VMA network.
Privilege
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 97h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command=0x0bh, used to set the VMA network |
| 5 | Data length(0x18) |
| 6:9 | CMC IP |
| 10:13 | CMC SUBMASK |
| 14:17 | CMC Gateway IP |
| 18:21 | HyperVisor IP |
| 22:25 | HyperVisor SUBMASK |
| 26:29 | HyperVisor Gateway IP |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Set the VMA network.
Request:
bash
ipmicmd -k "0f 00 MM NN" smi 0Response:
text
0f MM NN