Set Node Global Configuration ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Set the global configuration of the node.

Privilege ​

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD97h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command =08h
5bladeid, 1 based
6Node configuration parameters. For details, see Table 1.
7[7:1]: reserved
[0]: cascading flag
0: last data
1: middle data
8Offset, indicating the offset of the written data. The value starts from 0. Write data in sequence when they are written as multiple frames.
9Length: length of the data to be written.
10:NWritten data

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Set the global configuration of a node. ​

Request:

bash
ipmicmd -k "0f 00 MM NN" smi 0

Response:

text
0f MM NN

Back to Index ​