Set NC collect enable
更新时间: 2026/08/06
在Gitcode上查看源码Set NC collect enable
Change History
| openUBMC Version | Revision Date | Description |
|---|---|---|
| 25.06 | 2025/06/26 | Initial draft: add command details |
Basic Information
Function Description
Enable NC collection.
Privilege
ReadOnly
Command Information
Request Information
| Byte | Data Field |
|---|---|
| NetFn | 30h |
| CMD | 97h |
| 1:3 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
| 4 | Sub command, sub command =08h |
| 5 | bladeid, 1 based |
| 6 | Read/write status. 0x01: read/write |
| 7 | Concatenation flag. 0x00: last frame |
| 8 | Cascading offset. The default value is 0x00. |
| 9 | data length |
| 10 | NC one-click collection enable status 0x01-enable 0x00-disable |
Response Information
| Byte | Data Field |
|---|---|
| 1 | Completion Code |
| 2:4 | Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h. |
Command Example
Enable NC collection.
Request:
bash
ipmicmd -k "0f 00 30 97 db 07 00 08 01 01 00 00 ff 01" smi 0Response:
text
0f 31 00 97 d6