代码仓
中
Set NC collect enable
更新时间: 2026/08/06
在AtomGit上查看源码

Set NC collect enable ​

Change History ​

openUBMC VersionRevision DateDescription
25.062025/06/26Initial draft: add command details

Basic Information ​

Function Description ​

Enable NC collection.

Privilege ​

ReadOnly

Command Information ​

Request Information ​

ByteData Field
NetFn30h
CMD97h
1:3Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.
4Sub command, sub command =08h
5bladeid, 1 based
6Read/write status. 0x01: read/write
7Concatenation flag. 0x00: last frame
8Cascading offset. The default value is 0x00.
9data length
10NC one-click collection enable status
0x01-enable
0x00-disable

Response Information ​

ByteData Field
1Completion Code
2:4Manufacturer ID, LS Byte first. The length is fixed to three bytes. For example, if the vendor ID is 2011 and the corresponding hexadecimal value is 0x0007DB, the first byte is DBh, the second byte is 07h, and the third byte is 00h.

Command Example ​

Enable NC collection. ​

Request:

bash
ipmicmd -k "0f 00 30 97 db 07 00 08 01 01 00 00 ff 01" smi 0

Response:

text
0f 31 00 97 d6

Back to Index ​